You can change the information about fields in the Groups Tables in the Library Window. To change the name of the field, click on its current name, type in a new name and press the enter key.

 

The units for the field may also be modified. In the units column, type in the name of the units you want to use to store properties in this field. For example, if you added a field named Iw for a warping constant your units might be in^6 (inches to the sixth power) so you should type this into the units column. You should also type in a factor to convert the fields values into Section Maker's internal units system. This will allow you or another user to change units and still have the properties displayed correctly. The factor is the number the entered value must be multiplied by to convert it into a Newton, meter, kilogram units system. i.e. in the case where Iw will be entered in units of in^6, the factor will be 6.820907E-12 (i.e. 1/39.37 to the power of six as there are 39.37 inches in a meter)

 

Some common units factors are

 

 

 

Metric

 

English

 

Name

Property

Unit

Factor

Unit

Factor

Mass

Mass per unit length

kg/m

1.0

lb/ft

1.488

A, Asx, Asy

Cross sectional area

mm2

1E-6

in2

6.452E-4

Ix

Major moment of inertia

mm4

1E-12

in4

1.638E-5

Iy

Minor moment of inertia

mm4

1E-12

in4

1.638E-5

J

Torsion constant

mm4

1E-12

in4

1.638E-5

E

Young's Modulus

MPa

1E-6

ksi

6895000

G

Shear Modulus

MPa

1E-6

ksi

6895000

D

Depth

mm

0.001

in

0.0254

B

Breadth or Width

mm

0.001

in

0.0254

tf

Flange thickness

mm

0.001

in

0.0254

tw

Web thickness

mm

0.001

in

0.0254